Wall panel trim is ordered by type, not as a set. Work out the metres for each component from the elevation, total them separately, then round each total up to 3 m lengths.
Why trim is ordered by type
A wall uses four components, and the quantities are rarely close: a large flat wall can take ten times more H jointer than end cap. One combined figure means one type runs out while another sits in the store.
Step 1 – read the elevation first
Every line that covers a joint, a corner or a panel edge is one run of trim. Count the lines, then assign each to a type. A four-sided room is four elevations, not one perimeter.
Step 2 – put every line into one of four types
| Component | Runs along | How to count |
|---|---|---|
| H jointer (middle jointer) | panel-to-panel joints | (number of panels – 1) x run height |
| Internal corner | wall-to-wall and wall-to-ceiling inside corners | total length of those lines |
| External corner | external corners, columns and reveals | total length of those lines |
| End cap | panel edges that stop in the open, at openings | total length of those edges |
Step 3 – keep four totals
Do not add the four together and divide. On large commercial walls the H jointer is usually the largest by a wide margin, and internal corners normally outweigh external corners, a wall meets another wall or the ceiling more often than it ends in the open.
Step 4 – round each total up to 3 m lengths
3 m is the length most projects specify, so it is the figure to calculate on. Divide each total by 3 and round up: the small cuts at the end of a run come out of the last length, so no percentage is added on top. Where a run is shorter than 3 m, count runs rather than metres – that run takes a whole length.
We supply against measured quantities and we do not add a site allowance. How much spare a fixing team needs depends on the layout, the cutting and the sequence on site, and that judgement belongs to the contractor.
Worked example: a 12 m wall in 400 mm panels
12 m long, 3 m high, 400 mm panels, one door opening, two column corners.
| Component | Calculation | Metres | 3 m lengths |
|---|---|---|---|
| H jointer | 30 panels – 1 = 29 joints x 3 m | 87.0 | 29 |
| Internal corner | ceiling line 12 m + 2 returns of 3 m | 18.0 | 6 |
| External corner | 2 column corners x 3 m | 6.0 | 2 |
| End cap | door opening, 2 x 2.1 m | 4.2 | 2 |
| Total | 115.2 | 39 |
H jointer is 76 per cent of the total, end cap under 4 per cent. A combined figure would have hidden that, and the site would have run short of joints first.
Check each type against the minimum order
Ordering runs at 300 m per profile. A single wall rarely reaches that on the small components, which is why the split is taken across a project, not room by room. If one type falls short, say so in the enquiry.
Questions
Do I order the same quantity of each type?
No. Quantities follow the layout: a wide wall with few openings is mostly H jointer, a corridor with columns uses far more corners.
Should the supplier add a wastage percentage?
No. We quote the metres you measure. Site allowance is the contractor’s call, because it depends on how the panels are cut and fixed.
Can the trim be supplied in other lengths?
Yes. 3 m is the volume length; other lengths are made to order.
Send the elevation, the panel width and your component list – a quantity breakdown comes back within 24 hours.
Ordering the profiles themselves? The wall panel trim page sets out the inner heights, the corner pieces and the H jointers.